As Super Cell is embedded in the pile, so when pouring the concrete (especially under water), it will block the flowing of the concrete in some way. The blocking will make the section of Super Cell level a weak section, and influence the pile quality and the testing result. Ougan Super Cell adopt Cone-shape Flow guides to solve this problem effectively: Cone-shape Flow Guides will be precast with high strength concrete, to ensure there is no gap between Super Cell load surface and concrete. Duri...
Read More2017-08-18Different models of Super Cells and their embedment method are chosen to best fit different project conditions: 1. Burying the Super Cell at the pile toe allows for a dead load at the pile head to be installed, acting as an opposing force. Meanwhile, this makes the pile shaft skin friction and opposing force interact with the end bearing. 2. Choosing a smaller Super cell to obtain partial contact area with pile toe allows for skin friction to be completely supplied through the opposing force dur...
Read More2017-08-18Guizhou Provincial Regulations for bi-directional static load test of foundation piles has been published, and Ougan has participated in its composition. In addition, Ougan was also invited to write the regulations for Chinese provinces of Shandong, Guangxi, Guizhou, Gansu, Tianjin, and Yuannan (in progess). Other provinces not specified have also arranged to write their provincial regulations with Ougan Technology. ...
Read More2017-08-15As part of the Engineering Construction Regulations of Yunnan Province Technical Code for bi-directional load test method of foundation piles is in preparation! Ougan Technology, being part of a co-author of this code, was invited to attend and participate in the working conference to discuss the technical matter. ...
Read More2017-08-15On August 8, Ougan Technology partnered with the Shijiazhuang Construction Engineering Quality Inspection Association (CEQIA), to deliver a lecture on bi-directional static load test method. Held in Shijiazhuang city, Hebei province, China, the technical lecture was attended by around 60 members from local pile testing companies. At the conference, Mr. Gao, the Secretary General of CEQIA presented the Shijiazhuang city regulations for the bi-directional load testing method. Meanwhile, Ougan Tech...